Lennox mini-split systems are an excellent way to provide compact, yet effective temperature control for your home. Some models are built for air conditioning only, while heat pump models can deliver both heating and cooling.

But no home comfort system is flawless. There’s always a chance your mini-split could malfunction. To determine what happened, you’ll want to locate where the mini-split error codes are displayed. Understanding what these codes mean can help you kick-start mini-split repair, especially if professional help is required.

What each code means will ultimately depend on the specific model of your mini-split system. You can consult your manual for a guide for what each code means. You can also call the HVAC pros at Bishop Heating & Air Conditioning. Our technicians are trained to learn these codes in order to provide prompt mini-split repair in Bishop. Give us a call at 760-784-9034 to book an appointment.

Common Error Codes for Lennox Mini Splits

While error codes may differ from model to model, there are some codes you’ll be more likely to come across. To identify what your error code might mean, consider the following:

Is your system a mini-split air conditioner or a mini-split heat pump?

Are there other signs of what malfunctioned? A loud noise coming from an important component, for example.

Here are a few of the more common error codes for Lennox mini-splits.

E1 – Indoor / Outdoor Unit Communication

In general, an E1 error code indicates that communication between the mini-split system’s indoor and outdoor units has been impeded. It may be facing intermittent connection issues or have failed entirely. When the indoor and outdoor units can’t communicate with one another, it will not be able to properly balance indoor temperatures.

E5 – Voltage Protection or Temperature Sensor Error

If you own a mini-split heat pump, an E5 error could refer to a problem with the system’s voltage. A repair technician from Bishop Heating & Air Conditioning may refer to it as overcurrent protection. Both very high or low voltage can produce this error code.

For mini-split air conditioners, this code may also stand for voltage issues. In other cases, it’s alerting you to a circuit problem with the outdoor temperature sensor.

E6 – Indoor / Outdoor Unit Communication

An E6 error code can also refer to a communication problem between the two units, similar to an E1 code. It could also be an issue with one of the temperature sensors.

P4 – Compressor Drive Error / High Temperature

A P4 error code will generally be related to your mini-splits compressor system, found within the outdoor unit. When the compressor drive is malfunctioning, the most likely culprit is excessively high temperatures. A high temperature at the discharge line could also result in a P4 code.

P6 – Compressor Switch Open or Drive Board Failure

Your mini-split system will have computer boards that make sure the indoor and outdoor units can communicate with one another. If the drive board is malfunctioning, a P6 error code is common.

When temperatures rise above safe levels, a safety switch will protect the electrical components of your mini-split system, including any components that manage the outdoor compressor. If this switch is open, the P6 code could appear. You may also find the P6 code if the compressor is experiencing high or low pressure concerns.

Consult the Service Manual for Specifics

Keep in mind that in general, error codes are specific to each model of a Lennox mini-split system. Your manual will offer a guide for these error codes and what they should mean. But as many of these codes refer to electrical problems, professional experience is usually needed.